Benchtop pH/ORP/lon Meter PH-920 PH-930

Product origin CHINA

Delivery time Within 7 days

Supply capacity Factory Direct Supply

Automatic temperature compensation ensures accurate readings over the entire range.

 

  • Benchtop pH/ORP/lon Meter PH-920 PH-930

    Request a Call Back

    •  Ask a Question

      Benchtop pH/ORP/lon Meter PH-920 PH-930

      Ask a Question


        Share
      Benchtop pH/ORP/lon Meter PH-920 PH-930
      pH: *1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers. *Automatic electrode diagnosis shows the pH slope and offset. *Automatic temperature compensation ensures accurate readings over the entire range. *Calibration due alarm prompts user to calibrate the meter regularly. ORP: *1 point offset calibration allows adjusting the displayed value to a known standard. *Relative and absolute millivolt modes ensure the reliable ORP measurements.Ion Concentration(For PH-930). *2 to 5 points calibration, including the 8 concentration points can be selected. *Direct ion concentration readout simplifies the measurement process. *Automatic electrode diagnosis shows the calibration points and slopes. *Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency. General Features *Auto-Read function senses and locks the measurement endpoint. *Setup menu allows setting the pH buffer set, number of calibration points, resolution, stability criteria, temperature unit, date and time, etc. *Reset function automatically resumes all settings back to the factory defaults. *Expanded memory stores or recalls up to 500 data sets. *USB communication interface for data transfer and timed interval readings. Technical Parameters:
      Model PH-920 PH-930
      PH Range -2.000~20.000pH
      Accuracy ±0.002pH
      Resolution 0.1, 0.01, 0.001 pH, Selectable
      Calibration Points 1~5 points
      Calibration Solutions USA, NIST, DIN, 2 custom buffers
      ORP MV Range ±1999.9mV
      Relative mV Range ±1999.9mV
      Resolution 0.1,1mV, Selectable
      MV Accuracy ±0.2mV
      Calibration Points 1 point
      Ion Range / 0.001 ~19999ppm, mg/L, mol/L (deponding on the range of ISE)
      Resolution / 0.001,0.01,0.1,1
      Accuracy / ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
      Measurement Units / ppm, mg/L, mol/L, mmol/L
      Calibration Points / 2 to 5 points
      Calibration Solutions / 0.001,0.01,0.1,1,10,100, 1000,10000
      Temperature Range 0~105°C/32~221°F
      Resolution 0.1°C/0.1°F
      Accuracy ±0.5°C/±0.9°F
      Offset Calibration 1 point, reading ±10°C
      Other Specifications Temperature Compensation 0~100°C, Manual or Automatic
      Stability Criteria Low or high
      Calibration Due Alarm 1 to 31 days or off
      Slope/Offset Display Yes
      Hold Function Manual or auto-endpoint
      Memory 500 data sets
      Communication Interface USB
      Connector BNC, 3.5mm jack socket
      Display Custom LCD (125*100mm)
      Power Requirements DC5Vpower adapter
      Dimensions(mm) 210*188*60mm
      Weight(kg) 1.5kg
      Package Size(W*D*H)mm 310*240*180mm
      Gross weight(kg) 1.7kg
      Categories
      My Cart
      Categories