Benchtop pH/ORP/Ion Meter

Product origin CHINA

Delivery time Within 7 days

Supply capacity Factory Direct Supply

1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers
Automatic electrode diagnosis shows the pH slope and offset

  • Benchtop pH/ORP/Ion Meter

    Request a Call Back

    •  Ask a Question

      Benchtop pH/ORP/Ion Meter

      Ask a Question


        Share
      Benchtop pH/ORP/Ion Meter
      Features: pH: 1. 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers 2. Automatic electrode diagnosis shows the pH slope and offset 3. Solution temperature coefficient compensates for the pure water samples and references the pH to 25°C ORP: 1. 1 point offset calibration allows adjusting the displayed value to a known standard 2. Relative and absolute millivolt modes ensure the reliable ORP measurements Ion Concentration: 1. 2 to 5 points calibration, including the 8 concentration points can be selected 2. Electrode management is capable of storing and recalling up to 3 electrode slopes 3. Automatic electrode diagnosis shows the calibration points and slopes 4. Selectable ion measurement methods (direct reading, known addition, known subtraction, sample addition, sample subtraction) and concentration units (ppm, mg/L, mol/L or mmol/L) Water Hardness: 1. 2 to 5 points calibration from low to high concentrations 2. Selectable measurement units (German degree, English degree, French degree, mmol/L and mg/L) are used for professional water hardness measurements General Features: 1. Automatic temperature compensation ensures accurate readings over the entire range 2. Auto-Read function senses and locks the measurement endpoint 3. Timed Interval Readings sends the measurement data to a PC or printer 4. Limit Alarm automatically alerts when reading exceeds the specified range 5. Calibration due alarm prompts user to calibrate the meter regularly 6. Password protection prevents the unauthorized calibration and settings 7. Expanded memory stores or recalls up to 1000 data sets 8. Reset function automatically resumes all settings back to the factory defaults Technical Parameters: 
      Model PH-A120-CN PH-A120-UK PH-A130-CN PH-A130-UK PH-A131
      PH Range -2.000~20.000pH • • —
      Resolution 0.001, 0.01, selectable • • —
      Accuracy ±0.002pH • • —
      Calibration Points 1 to 5 points • • —
      pH Buffer Options USA, NIST, DIN, 5 custom buffers • • —
      ORP(optional) mV Range ±2000.0mV • • •
      Relative mV Range ±2000.0mV • • —
      Resolution 0.1mV • • •
      Accuracy ±0.2mV • • •
      Calibration Points 1 point • • —
      Ion Range 0.001~30000 (depending on the range of ISE) — • •
      Resolution 0.001, 0.01, 0.1, 1 — • •
      Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent) — • •
      Measurement Units ppm, mg/L, mol/L, mmol/L — • •
      Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) — • •
      Measurement Methods Direct reading, known addition, known subtraction, sample addition, sample subtraction — • •
      Electrode Management 1 to 3 electrodes — • •
      Water Hardness Range 0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) — • •
      Resolution 0.001, 0.01, 0.1, 1 — • •
      Accuracy ±1% F.S. — • •
      Calibration Points 2 to 5 points (0.01, 0.1, 1, 10, 100mmol/L) — • •
      Temperature Range 0~105°C/32~221°F • • •
      Resolution 0.1°C/0.1°F • • •
      Accuracy ±0.5°C/±0.9°F • • •
      Offset Calibration 1 point, reading ±10°C • • •
      Other Specifications Temperature Compensation 0~100°C, manual or automatic • • •
      Solution Temperature Coefficient 25°C • • —
      Stability Criteria Standard or high-accuracy • • •
      Calibration Due Alarm 1 to 31 days or off • • •
      Interval Readings 10, 30, 60 seconds, 10, 30 minutes or off • • •
      Password Protection 4 digits • • •
      Memory 1000 data sets • • •
      Communication Interface USB • • •
      Connector BNC, 3.5 mm jack socket • • •
      Display 7 inches TFT LCD • • •
      Power Supply Standard: 220V 50/60Hz; Optional: 110V, 50/60Hz;  DC12V power adapter • • •
      Outer Dimensions 240*220*80mm
      Net Weight 1.7kg
      Packing Size 320*250*200mm
      Gross Weight 1.8kg
      Remarks: • means with; — means without. Difference of PH-A120/130-CN& PH-A120/130-UK: 1. PH-A120/130-CN electrode is E201-BNC plastic body pH electrode, PH-A120/130-UK electrode is P11 glass pH electrode 2. PH-A120/130-UK is more accurate than PH-A120/130-CN Ordering Information: 1. PH-A120/130-CN: Meter, E201-BNC plastic body pH electrode, temperature probe, pH buffer sachets, electrode holder and power adapter 2. PH-A120/130-UK: Meter, P11 glass pH electrode, temperature probe, pH buffer sachets, electrode holder and power adapter 3. PH-A131: Meter, ion selective electrode, temperature probe, standard solutions (100/1000ppm), ionic strength adjuster, electrode holder and power adapter