Benchtop Dissolved Oxygen Meter

Product origin CHINA

Delivery time Within 7 days

Supply capacity Factory Direct Supply

Features:
*1 or 2 points calibration using the air-saturated water or zero oxygen solution.
*Salinity and barometric pressure compensations eliminate the measurement error.
*Automatic temperature compensation ensures accurate readings over the entire range.
*Auto-Read function senses and locks the measurement endpoint.
*Setup menu allows setting the number of calibration points, concentration unit, temperature unit, etc.
*Reset function automatically resumes all settings back to the factory defaults.
*Calibration due alarm prompts user to calibrate the meter regularly.(only PH-980)
*Set up menu allows setting the number of calibration points,resolution.stability criteria, temperature unit, concentration unit, date and time, etc,(only PH-980)
*Expanded memory stores or recalls up to 500 data sets.(only PH-980)SD
*USB communication interface for data transfer and timed interval readings.(only PH-980)
Accessories:
DO100 dissolved oxygen electrode, electrolyte solution, membrane cap and DC9V power adapter.

  • Benchtop Dissolved Oxygen Meter

    Request a Call Back

    •  Ask a Question

      Benchtop Dissolved Oxygen Meter

      Ask a Question


        Share
      Benchtop Dissolved Oxygen Meter
      Technical Parameters:
      Model PH-810 PH-980
      DO Range 0.0~20.0mg/L or ppm
      Accuracy ±0.5mg/L ±0.2mg/L
      Resolution 0.1mg/L 0.01, 0.1mg/L, selectable
      % saturation Range 0.0-200.0%
      Accuracy ±2.0%
      Resolution 1% 0.1,1%, selectable
      Temperature Range 0-60°C/32-140°F
      Accuracy ±1°C/±1.8°F ±0.5°C/±0.9°F
      Resolution 0.1°C/0.1°F
      Offset Calibration 1 point, reading ±10°C
      Other Specifications Dissolved Oxygen Calibration 1 or 2 points
      Temperature Compensation 0~40°C, automatic 0〜50°C, automatic
      Barometric Pressure Correction 60.0~112.5kPa/450〜850mmHg, manual
      Salinity Correction 0.0~35.0g/L, manual 0.0~50.0g/L, manual
      Stability Criteria / Low or high
      Calibration Due Alarm / 1 to 31 days or off
      Hold Function Manual or auto-endpoint
      Memory / 500 data sets
      Communication Interface / USB
      Connector 6-pin nimi-DIN
      Display Custom LCD (120*60mm) Custom LCD (125*100mm)
      Power Requirements DC9V power adapter DC5V power adapter
      Dimensions(mm) 210*205*75mm 210*188*60mm
      Weight(kg) 1.5kg
      Package Size(W*D*H)mm 310*240*180mm
      Gross weight(kg) 1.7kg