BK-AA4530F Atomic Absorption Spectrophotometer

Product origin CHINA

Delivery time Within 7 days

Supply capacity Factory Direct Supply

Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

 

  • BK-AA4530F Atomic Absorption Spectrophotometer

    Request a Call Back

    •  Ask a Question

      BK-AA4530F Atomic Absorption Spectrophotometer

      Ask a Question


        Share
      BK-AA4530F Atomic Absorption Spectrophotometer
      Features: * Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional). * Integrated floated optical platform design improves the optical system shock resistance stable. * Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp. * Position adjusting: the flame burner can be set on the best position automatically. * Fully automated wavelength scanning and peak searching. * Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout. * Deuterium lamp and self-absorption background calibration. * Measuring method: flame absorption method and emission method. * Result printing: parameter, data result and diagram. * Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format. Technical Parameters:
      Model BK-AA4530F
      Wavelength Range 190~900nm
      Spectral Bandwidth 0.1, 0.2, 0.4,1.0 and 2.0nm
      Wavelength Accuracy ≤±0.15nm
      Wavelength Repeatability ≤0.04nm
      Base Line Stability ≤0.002A/30min (Cu)
      Characteristic Concentration 0.02μg/ml/1% (Cu)
      Detection Limit 0.004μg/ml (Cu)
      Preciseness ≤0.5%
      Grating 1800 lines/mm
      Inflamer All-metal titanium burner
      Atomizer Effective glass atomizer
      Lamp Stand 8
      D2 background Calibration When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
      Power Supply 220V, 50Hz
      Packing Size(W*D*H) mm 860*705*755 (Main instrument); 545*445*1385 (Accessories)
      Gross Weight(kg) 105 (Main instrument); 100 (Accessories)
      Standard Accessories Software; Inkjet printer; Oil free Air compressor; Acetylene reducing valve; Cu Hollow cathode lamp; Air filter
      Optional Accessories Graphite Furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler
      Flame System:
      Acetylene Air Burner 100mm
      Ignition Dynamic Baseline Drift ≤0.006A/30min
      Characteristic Concentration ≤0.025μg/ml/1%(Cu)
      Related Standard Deviation of the Accuracy ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
      Safety System Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.
      Graphite Furnace(Optional):
      Max. Temperature 3000°C
      Max Heating Speed ≥2000°C/S
      Characteristic Quantity Cd≤0.5*10T2g Cu≤0.5*1011g
      Accuracy Cu≤3% Cd≤3%
      Safety System Over current protection Low air pressure alarm/protection; Low cooling water flow alarm/protection
      Power Supply 220V, 50Hz
      Consumption 7000W
      Packing Size(W*D*H) mm 740*640*700
      Gross Weight(kg) 90