Benchtop Grating Spectrophotometer BK-GS6060

Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Introduction:
BK-GS6060 is a benchtop grating spectrophotometer, which has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry (including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes BK-GS6060 ideal for color analysis within R&D and laboratory environments.
Benchtop Grating Spectrophotometer BK-GS6060
Request a Call Back
- Ask a Question
Benchtop Grating Spectrophotometer BK-GS6060
Ask a Question
Model | BK-GS6060 |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nm Cut-off light source, UV Lamp |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semi-band Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive: Φ30mm/Φ25.4mm; |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN |
Color Difference Formula | ΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1) , ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter, YI (ASTM D1925, ASTM 313),TI (ASTM E313, CIE/ISO), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles) |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB & Bluetooth |
Data Storage | Standard 5000 Pcs, Sample 40000 Pcs (One PCS can include both SCI and SCE) |
Language | Chinese, English |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | White and Black Calibration Board, Checking Green Board, Sample Holder,∮4mm, ∮8mm, ∮15mm, ∮25.4mm Aperture, Power Adapter, USB Cable, User Guide, PC Software |
Optional Accessory | Micro printer, Transmissive Test Clamp Component |
Power Supply | DC 24V, 3A; Power adapter: 110~230V 50/60HZ |
External Size(L*W*H) | 370*300*200mm |
Weight | 9.6kg |
Package Size (W* D*H) | 350*470*520mm |
Gross Weight | 18kg |
- Wireless Handheld Ultrasound
- Disinfection And Sterilization Equipments
- Molecular Laboratory Equipments
- Air Protection Product
- Laboratory Temperature Control Equipments
- Other Lab Equipments
- Peristaltic Pump
- Vacuum Pump
- Safety Storage Cabinet
- Dehumidifier
- Ultrasonic Cleaner
- Automatic Medical Sealer
- Water Distiller
- Water Purifier
- Gas Generator
- Shaker
- Jacketed Glass Reactor
- Stirrer
- Jar Tester
- laboratory furniture
- Liquid Nitrogen Container
- Static Storage Liquid Nitrogen Tank
- Mouse Cage
- Cleanroom Panels
- Centrifuge
- Optical Instruments
- Medical Consumables
- Liquid Processing Instruments
- Doppler Ultrasound
- Laboratory Incubator
- Microbiological Laboratory Instruments
- Laboratory Solid Processing Equipments
- B/W Ultrasound
- Drying Oven
- Blood Bank Instruments
- Pre-Processing Of Bio-Samples
- Electrocardiogram
- Laboratory Analysis Equipments
- COD Analyzer
- Titrator
- Water Activity Meter
- Colorimeter
- Turbidimeter
- Cooking Oil Tester
- Viscometer
- Densimeter
- Soil Nutrient Tester
- Fat Analyzer
- Automobile Exhaust Analyzer
- Fiber Analyzer
- Leakage Tester
- Flash Point Tester
- Melting Point Apparatus
- Laboratory Balance
- Grain Moisture Meter
- Carbon And Sulfur Analyzer
- PH Meter
- Pharmacy Instruments
- Patient Monitor
- Pathology Lab Equipments
- Rehabilitation Products
- Clinical Analytical Instruments
- Diagnostic X-ray Equipment
- Laboratory And Medical Cryogenic Equipments
- Medical Equipments
Related Products
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Model BK-D9X
Introduction:
This instrument employs a pulsed xenon lamp as the light source. It can be utilized normally for at least 7 years without the need for light source replacement. We implement unique designs in optics, circuits, structure, advanced process specifications, and a rigorous quality management system. The microcomputer governs and processes data. A large color screen is utilized for display, along with graphical interface operation and user-friendly menu prompts.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Features For BK-F96PRO
1. Two operation modes fluorescence intensity and luminous intensity.
2. 365nm exciting wavelength,Raman peak of water S/N ≥150.
3. 10 stages emission spectrum scanning.
4. Support off-line mode and on-line mode. Features for BK-F93
5. 1200 line diffraction grating emission monochromator .
6. LED is a cold-light source with longevity, lower background & reliability, prevent from thermo-pollution.
7. Automatic zero adjustment and automatic background subtraction,
8. Eight stage sensitivity adjustment, Real time fluorescence value display and concentration print out,.Extra wide dynamic range of fluorescence value ensures accurate measurement of minute changes in micro samples.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Application:
Micro-Volume Spectrophotometer is used for quantitative and qualitative research by spectrophotometry.
It is usually used in quantitative research of nucleic acid, proteins and bacterial concentration.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Features:
1. Environmental Deuterium lamp, preventing from Ozone inhalation.
2. Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp.
3. Socket-Type Deuterium lamp and Tungsten lamp.
4. GLP self-check function:check the wavelength accuracy and Photometry accuracy,provide test report and power-off protection.
5. Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically.
6. Si02 coating optical mirror, reduces the influence from outside.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Features:
1. Build-in computer data processing and LCD display.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
3. Quickly: The cathode lamp does not need to be pre-heated for long time and sample can be analyzed immediately.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
6. High energy optical path.
7. Long-life and anti-corrosive atomization system.
8. Multi-functional analysis mode: ?flame absorption?flame emission? graphite furnace atomic absorption ④ hydride generation.
9. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Features:
1. With GLP self-check function, check the wavelength accuracy and Photometry accuracy.
2. Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically.
3. With Si02 coating optical mirror, reducing the pollution from outside fully.
4. PC Software to expand the applications to Quantitative, Multi-Wavelength and Kinetics, Spectrum Scanning, DNA/Protein test for PC Series.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Introduction:
The UV-Vis Spectrophotometer is an analytical instrument based on the principle of ultraviolet visible spectrophotometry, which uses the radiation absorption of molecules in the ultraviolet visible spectral region for analysis. It is widely used in various fields such as medicine and health, environmental monitoring, life sciences, drug analysis, food analysis, organic chemistry, biochemistry, etc.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Features:
*USB Interface(Except BK-FP640)
*LPG as burning gas
*Direct concentration read-out(Except BK-FP640)
*Measuring range adjustable
*7 inch LCD touch screen
*Automatic Calculation of correlation
coefficient(Except BK-FP640)
*Pre-selection of flame sizes
*Flameout protection device
*Optional built-in printer(Except for BK-FP640)
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Model BK-D2600
Introduction:
The Double Beam Scanning UV/VIS Spectrophotometer is a sophisticated analytical instrument designed for precise and comprehensive measurement of ultraviolet (UV) and visible (VIS) light absorbance. Ideal for use in research, quality control, and environmental analysis, this spectrophotometer provides accurate, reliable data across a wide range of wavelengths, making it essential for various scientific and industrial applications.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Easy to operate, no sample preparation is required, and the sample is not damaged.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Features:
*The uniquely designed sample holder can test a smallamount of DNA and protein.
*Detection is rapid, drop sample – rotation – detection*The whole measurement process without light loss, toensure the accuracy of the results
*The function can be expanded, and can complete
quantitative testing, wavelength scanning, kinetics,multi-wavelength and other functions,and can also beused for conventional colorimetric blood measurement.
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Features:
1. Adopted high-class grating with wholly hermetic light path design, to ensure the instrument has the super low stray light.
2. Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system.
3. With GLP self-check function, check the wavelength accuracy and Photometry accuracy.
4. Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically.
5. With Si02 coating optical mirror, reducing the pollution from outside fully